Mounting Type
DIN Rail Mount
Surface Mount
having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.
NO
Number of Terminals
13
Manufacturer Part Number
85693
Approvals
cULus, cURus
Input Frequency
The Input Frequency refers to the frequency that mobiles and portables transmit on to access a Repeater.
50-60 Hz
Manufacturer
Murrelektronik
Mounting
DIN Rail
No. of outputs
1x
Dim
(L x W x H) 182 x 109 x 138 mm
Connections
Spring-loaded terminal
Manufacturer part #
85693
Input voltage (max.)
572V AC,745V DC
Max. operating temperature
+70°C
Max. output current
48A
Inputs
2.3A
Output voltage (max.)
28V DC
Min. temperature
-40°C
Content
1pc(s)
Output voltage (min.)
24V DC
Max. temperature
+70°C
Output current (max.) - rounded
48A
Min. input voltage
324V AC,480V DC
Output voltage (nominal)
28V DC
Modular version
Yes
Type of electric connection
Spring clamp connection
Degree of protection (IP)
IP20
SIL according to IEC 61508
None
Rail mounting possible
Yes
Suitable for safety functions
Yes
Voltage type of supply voltage
AC/DC
Minimum Temperature
-40°C
Special Features
Optimum Performance, Reliable, Space Saving
Standards Met
cULus, cULus Recognised, EN 55011 B, EN 60715, EN 60950-1, EN 61000-3-2, EN 61204-3, SEMI F47
Maximum Temperature
+70°C
Maximum Operating Temperature
the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.
+ 70 C
Unit Weight
6.305 lbs
Open Frame/Enclosed
Enclosed
Minimum Operating Temperature
- 40 C
Factory Pack QuantityFactory Pack Quantity
1
Mounting Styles
DIN Rail Mount
Brand
Murrelektronik
RoHS
Details
Package Description
,
Package Style
MICROELECTRONIC ASSEMBLY
Package Body Material
UNSPECIFIED
Operating Temperature-Min
-40 °C
Reflow Temperature-Max (s)
NOT SPECIFIED
Operating Temperature-Max
70 °C
Rohs Code
Yes
Input Voltage-Max
572 V
Package Shape
RECTANGULAR
Part Life Cycle Code
Active
Input Voltage-Min
324 V
Ihs Manufacturer
MURRELEKTRONIK GMBH
Output Voltage-Nom
24 V
Risk Rank
5.71
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-40-158 °F
Series
EMPARRO
Packaging
Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.
Bulk
Type
Murr Elektronik
Additional Feature
Any Feature, including a modified Existing Feature, that is not an Existing Feature.
ALSO OPERATES IN 480 TO 745 VDC
Subcategory
AC-DC Power Supply
Power Rating
960W
Technology
HYBRID
Terminal Position
UNSPECIFIED
Terminal Form
Occurring at or forming the end of a series, succession, or the like; closing; concluding.
UNSPECIFIED
Peak Reflow Temperature (Cel)
NOT SPECIFIED
Number of Functions
1
Depth
182
Reach Compliance Code
unknown
JESD-30 Code
R-XXMA-X13
Number of Outputs
1
Efficiency
93.50%
Output Voltage
24V dc
Input Voltage-Nom
360 V
Temperature Grade
Temperature grades represent a tire's resistance to heat and its ability to dissipate heat when tested under controlled laboratory test conditions.
OTHER
Trim/Adjustable Output
YES
Analog IC - Other Type
AC-DC REGULATED POWER SUPPLY MODULE
Output Current
The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.
30 A
Input Type
3-Phase / Three Phase
Total Power Output-Max
1152 W
Product Type
a group of products which fulfill a similar need for a market segment or market as a whole.
DIN Rail Power Supplies
Output Voltage-Max
28 V
Output Voltage-Min
24 V
Overload Protection
Overload protection is a protection against a running overcurrent that would cause overheating of the protected equipment. Hence, an overload is also type of overcurrent. Overload protection typically operates on an inverse time curve where the tripping time becomes less as the current increases.
Yes
Product
Switching Supplies
Nominal Input Voltage (AC)
347 VAC, 575 VAC
Input Voltage
400V ac
Product Category
a particular group of related products.
DIN Rail Power Supplies
Width
109mm
Height
138mm
Length
182mm