54502

Murr Elektronik 54502

Part No:

54502

Manufacturer:

Murr Elektronik

Datasheet:

-

Package:

-

AINNX NO:

35958118-54502

Description:

Murrelektronik I/O Modules, Solid67 Series

Products specifications
  • Mounting Type
    Panel Mount
  • Mounting Feature

    a process by which the operating system makes files and directories on a storage device (such as hard drive, CD-ROM, or network share) available for users to access via the computer's file system.

    Flange
  • Contact Shape
    Circular
  • Shell Material
    Aluminum Alloy
  • Insert Material
    Plastic
  • Lead Free Status / RoHS Status
    --
  • Contact Sizes
    20
  • Device Type
    Compact Module
  • Manufacturer Part Number
    54502
  • Approvals
    cULus
  • Manufacturer
    Murrelektronik
  • RoHS-compliant
    Yes
  • Connections
    Screws
  • Manufacturer part #
    54502
  • Min. temperature
    -20°C
  • Content
    1pc(s)
  • Max. temperature
    +70°C
  • Total no. of pins
    5
  • Supporting protocol for PROFINET IO
    Yes
  • Number of HW-interfaces parallel
    2
  • Supporting protocol for other bus systems
    No
  • Number of digital inputs
    0
  • Type of output voltage
    DC
  • Type of electric connection
    Screw connection
  • Supply voltage DC
    18 - 30
  • Fieldbus connection over separate bus coupler possible
    Yes
  • Supporting protocol for ASI
    No
  • Number of interfaces PROFINET
    2
  • Supporting protocol for EtherNet/IP
    Yes
  • Short-circuit protection, outputs available
    Yes
  • Supporting protocol for Data-Highway
    No
  • Supporting protocol for SERCOS
    No
  • Number of HW-interfaces serial TTY
    0
  • Number of HW-interfaces Wireless
    0
  • Supporting protocol for INTERBUS-Safety
    No
  • Radio standard Wi-Fi 802.11
    No
  • Supporting protocol for DeviceNet
    No
  • Degree of protection (IP)
    IP65/IP67
  • Supporting protocol for INTERBUS
    No
  • SIL according to IEC 61508
    None
  • System accessory
    Yes
  • Supporting protocol for LON
    No
  • Number of HW-interfaces industrial Ethernet
    2
  • Wall mounting/direct mounting
    Yes
  • Rail mounting possible
    No
  • Supporting protocol for DeviceNet Safety
    No
  • Supporting protocol for PROFINET CBA
    No
  • Number of HW-interfaces USB
    1
  • Supporting protocol for PROFIsafe
    No
  • Suitable for safety functions
    No
  • Supporting protocol for KNX
    No
  • Permitted voltage at output
    24 - 24
  • Supporting protocol for SafetyBUS p
    No
  • Supporting protocol for CAN
    No
  • Number of digital outputs
    16
  • Radio standard UMTS
    No
  • Explosion safety category for gas
    None
  • Number of HW-interfaces RS-485
    0
  • Rack-assembly possible
    No
  • Front built-in possible
    No
  • Radio standard GSM
    No
  • Appendant operation agent (Ex ib)
    No
  • Supporting protocol for MODBUS
    No
  • Number of HW-interfaces RS-232
    0
  • Number of HW-interfaces RS-422
    0
  • Appendant operation agent (Ex ia)
    No
  • Supporting protocol for Foundation Fieldbus
    No
  • Supporting protocol for SUCONET
    No
  • Supporting protocol for AS-Interface Safety at Work
    No
  • Supporting protocol for TCP/IP
    Yes
  • Type of digital output
    Transistor
  • Voltage type of supply voltage
    DC
  • Explosion safety category for dust
    None
  • Radio standard Bluetooth
    No
  • With optical interface
    No
  • IO link master
    No
  • Radio standard GPRS
    No
  • Digital outputs configurable
    No
  • Supporting protocol for PROFIBUS
    No
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -55°C ~ 175°C
  • Series
    Military, MIL-DTL-26482 G Series II, AFD
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    --
  • Connector Type
    Receptacle Housing
  • Type
    For Female Sockets
  • Number of Positions
    26
  • Fastening Type

    There are 5 Main Types of Fastening Type: Screws, Nails, Bolts, Anchors, Rivets.

    Bayonet Lock
  • Contact Type
    Crimp
  • Orientation
    W
  • Shielding
    Unshielded
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    Environment Resistant
  • Depth
    200
  • Shell Finish
    Chromate over Cadmium
  • Shell Size - Insert
    16-26
  • Housing Color
    Olive Drab
  • Note
    Contacts Not Included
  • Shell Size, MIL
    --
  • Includes
    --
  • Connection Type
    M12
  • Features
    --
  • IP Rating

    IP (or "Ingress Protection") ratings are defined in international standard EN 6529 (British BS EN 6529:1992, European IEC 659:1989). They are?used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies?(tools, dirt etc) and moisture.

    IP67
  • Width
    60mm
  • Height
    30.7mm
  • Length
    200mm
  • Material Flammability Rating
    --
0 Similar Products Remaining