MGJ3T24150505MC

Murata Power Solutions MGJ3T24150505MC

Part No:

MGJ3T24150505MC

Datasheet:

-

Package:

-

AINNX NO:

69864214-MGJ3T24150505MC

Description:

DC-DC Regulated Power Supply Module

Products specifications
  • Lifecycle Status
    Production (Last Updated: 5 months ago)
  • Mount
    Surface Mount
  • Weight
    10.7 g
  • Case/Package
    SMD/SMT
  • RoHS
    Compliant
  • SwitchingFrequency
    100 kHz
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    105 °C
  • Min Operating Temperature
    -40 °C
  • Power Rating
    3 W
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    2.4 W
  • Depth
    14.65 mm
  • Number of Outputs
    2
  • Efficiency
    81 %
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    36 V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    18 V
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    155 mA
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    150 mA
  • Topology
    Buck-Boost
  • Nominal Input Voltage

    The actual voltage at which a circuit operates can vary from the nominal voltage within a range that permits satisfactory operation of equipment. The word “nominal” means “named”.

    24 V
  • Max Duty Cycle
    75 %
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    5.2 kV
  • Height
    14.64 mm
  • Length
    31.24 mm
  • Width
    22.61 mm
  • REACH SVHC
    Yes