Lifecycle Status
Production (Last Updated: 4 months ago)
Factory Lead Time
8 Weeks
Contact Plating
Contact plating (finish) provides corrosion protection for base metals and optimizes the mechanical and electrical properties of the contact interfaces.
Gold
Mount
Surface Mount
Mounting Type
BOARD
Shell Material
COPPER ALLOY
Material
Thermoplastic
Housing Material
Plastic
Number of Terminals
5
Mounting Option 1
LOCKING
Board Mounting Option
PEG
Mounting Option 2
FRICTION LOCK
Panel Mount
No
Contact Materials
Copper
Country of Origin
JP
Manufacturer Lifecycle Status
ACTIVE (Last Updated: 4 months ago)
Schedule B
8536695050
Voltage Rating (AC)
30 V
Body Orientation
Right Angle
Termination Method
Solder
Base/Housing Material
Plastic
Mounting
Surface Mount
Component Type
Receptacle
Operating Temperature Max Deg. C
50C
Voltage Rating Max
30VDC/30VAC
Product Depth (mm)
6.7(mm)
Operating Temp Range
0C to 50C
Product Diameter (mm)
Not Required(mm)
Mounting Styles
Surface Mount
Operating Temperature Min Deg. C
0C
Pitch (mm)
0.8(mm)
Connections
SMT
Manufacturer part #
513870530
Packaging type
Tape on Full reel
Min. temperature
0°C
Nominal voltage (details)
30V DC/AC
Content
1200pc(s)
USB type
Mini B
Connector standard
USB 2.0
Max. temperature
+50°C
Nominal current (details)
1A
Factory colour
Black
Voltage, Rating
30 V
Maximum Operating Temperature
the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.
+ 50 C
Unit Weight
0.010582 oz
Minimum Operating Temperature
0 C
Factory Pack QuantityFactory Pack Quantity
1200
Part # Aliases
0513870530
Manufacturer
Molex
Brand
Molex
RoHS
Details
Package Description
LEAD FREE
Contact Finish Mating
GOLD (30)
Body Length
0.303 inch
Insulator Material
GLASS FILLED POLYETHYLENE
Operating Temperature-Max
50 °C
Rohs Code
Yes
Manufacturer Part Number
51387-0530
Part Life Cycle Code
Active
Samacsys Description
USB Connectors USB MINI-B RCPT R/A
Ihs Manufacturer
MOLEX LLC
Number Of Connectors
ONE
Risk Rank
1.61
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
0 to 50 °C
Packaging
Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.
Tape and Reel
Series
51387
JESD-609 Code
e3
Pbfree Code
Yes
Number of Terminations
5
Termination
Solder
ECCN Code
EAR99
Connector Type
Receptacle, USB
Type
Mini-B
Number of Positions
5
Max Operating Temperature
The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.
50 °C
Min Operating Temperature
0 °C
Color
Black
Applications
Wire-to-Board
Number of Rows
1
Gender
Female
Additional Feature
Any Feature, including a modified Existing Feature, that is not an Existing Feature.
SHIELDED
HTS Code
HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.
8536.69.40.30
Subcategory
USB Connectors
MIL Conformance
NO
DIN Conformance
NO
IEC Conformance
NO
Filter Feature
NO
Mixed Contacts
NO
Option
GENERAL PURPOSE
Pitch
800 µm
Total Number of Contacts
5
Orientation
Right Angle
Terminal Pitch
The center distance from one pole to the next.
0.7874 mm
Reach Compliance Code
compliant
Current Rating
Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.
1 A
Shell Finish
TIN
Reference Standard
UL
Termination Style
SMD/SMT
Reliability
COMMERCIAL
Number Of PCB Rows
1
Number of Contacts
5
PCB Contact Pattern
RECTANGULAR
Body Breadth
0.169 inch
Contact Gender
FEMALE
UL Flammability Code
94V-0
Empty Shell
NO
Body Depth
0.264 inch
Rated Current (Signal)
1 A
Contact Resistance
50 mΩ
Insulation Resistance
The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.
100 MΩ
Body/Shell Style
RECEPTACLE
Number of Circuits
5
Termination Type
SURFACE MOUNT
Plating
Tin
Polarization Key
POLARIZED HOUSING
Dielectric Withstanding Voltage
141VAC V
Number of Ports
A port is identified for each transport protocol and address combination by a 16-bit unsigned number,.
1
Contact Finish Termination
Tin (Sn)
Max Voltage Rating (DC)
3.03 kV
Halogen Free
Low Halogen
Product Type
a group of products which fulfill a similar need for a market segment or market as a whole.
USB Connectors
Shielded
Yes
Current Rating (Max)
1/Contact(A)
USB
USB 2.0
Glow Wire Compliant
Non-compliant
Product
Mini USB Type B Connectors
Mounting Angle
Right Angle
Features
+ shielding,+ locking mechanism
Standard
USB
Product Category
a particular group of related products.
USB Connectors
Product Length
9.1 mm
IP Rating
IP (or "Ingress Protection") ratings are defined in international standard EN 6529 (British BS EN 6529:1992, European IEC 659:1989). They are?used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies?(tools, dirt etc) and moisture.
-
Product Length (mm)
9.1(mm)
Product Height (mm)
4.4(mm)
Radiation Hardening
Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.
No
RoHS Status
RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.
RoHS Compliant
REACH SVHC
Unknown