LPH12A99-BWHR

Mechatronics LPH12A99-BWHR

Part No:

LPH12A99-BWHR

Manufacturer:

Mechatronics

Datasheet:

-

Package:

8-SMD, No Lead

AINNX NO:

39500121-LPH12A99-BWHR

Category:

AC Fans

Description:

FAN AXIAL 120X38MM 90-264VAC

Products specifications
  • Mounting Type
    Surface Mount
  • Package / Case
    8-SMD, No Lead
  • Weight
    -
  • Material - Frame
    Plastic
  • Material - Blade
    Plastic
  • Package
    Tape & Reel (TR)
  • Base Product Number
    580
  • Mfr
    CTS-Frequency Controls
  • Product Status
    Active
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    100 ~ 240VAC
  • Lifetime @ Temp.
    50000 Hrs @ 25°C
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 85°C
  • Series
    580
  • Size / Dimension
    0.197 L x 0.126 W (5.00mm x 3.20mm)
  • Termination
    2 Wire Leads
  • Type
    VCTCXO
  • Power (Watts)
    9.50W
  • Current Rating (Amps)
    0.180A
  • Voltage - Supply
    3V
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    -
  • Frequency
    19.2 MHz
  • Frequency Stability

    the variation of output frequency of a crystal oscillator due to external conditions like temperature variation, voltage variation, output load variation, and frequency aging.

    ±280ppb
  • Output
    Clipped Sine Wave
  • Function
    -
  • Base Resonator
    Crystal
  • Current - Supply (Max)
    6mA
  • Approval Agency
    CE, cUL, TUV, UL
  • Current - Supply (Disable) (Max)
    -
  • Spread Spectrum Bandwidth

    In telecommunication and radio communication, spread-spectrum techniques are methods by which a signal (e.g., an electrical, electromagnetic, or acoustic signal) generated with a particular bandwidth is deliberately spread in the frequency domain, resulting in a signal with a wider bandwidth.

    -
  • RPM
    3500 RPM
  • Bearing Type

    there are several different types of bearings, including ball and roller bearings, linear bearings, as well as mounted versions that may use either rolling element bearings or plain bearings.

    Ball
  • Fan Type

    There are three main types of fans used for moving air, axial, centrifugal (also called radial) and cross flow (also called tangential).

    Tubeaxial
  • Air Flow

    the movement of air

    123.9 CFM (3.47m³/min)
  • Noise
    49.0dB(A)
  • Voltage Range
    90 ~ 264VAC
  • Static Pressure

    the force per unit area that is exerted by a fluid upon a surface at rest relative to the fluid.

    0.360 in H2O (89.6 Pa)
  • Absolute Pull Range (APR)
    ±5ppm
  • Features
    Auto Restart, Electronic Commutation (EC)
  • Height Seated (Max)
    0.079 (2.00mm)
  • Width
    38.50mm
  • Ratings
    -