ODD-632-007

Lumex ODD-632-007

Part No:

ODD-632-007

Manufacturer:

Lumex

Datasheet:

-

Package:

1206 (3216 Metric)

AINNX NO:

41044975-ODD-632-007

Description:

RED ENHANCED 3.1MM2 BI-CELL PHOT

Products specifications
  • Mounting Type
    Surface Mount, MLCC
  • Package / Case
    1206 (3216 Metric)
  • Package
    Tape & Reel (TR)
  • Mfr
    Vishay Vitramon
  • Product Status
    Active
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    25V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -55°C ~ 150°C
  • Series
    GA
  • Size / Dimension
    0.126 L x 0.063 W (3.20mm x 1.60mm)
  • Tolerance
    ±5%
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    X8R
  • Applications
    Automotive
  • Capacitance
    10000 pF
  • Failure Rate

    the frequency with which an engineered system or component fails, expressed in failures per unit of time. It is usually denoted by the Greek letter λ (lambda) and is often used in reliability engineering.

    -
  • Lead Spacing

    the distance between two baselines of lines of type. The word 'leading' originates from the strips of lead hand-typesetters used to use to space out lines of text evenly. The word leading has stuck, but essentially it's a typographer's term for line spacing.

    -
  • Diode Type
    -
  • Lead Style
    -
  • Viewing Angle

    the angle at which a display can be viewed with acceptable visual performance.

    80°
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    8ns, 190ns
  • Voltage - DC Reverse (Vr) (Max)
    60 V
  • Wavelength
    -
  • Spectral Range
    250nm ~ 1100nm
  • Active Area
    -
  • Features
    -
  • Current - Dark (Typ)
    900pA
  • Color - Enhanced
    Red
  • Responsivity @ nm
    0.36 A/W @ 633nm, 0.6 A/W @ 900nm
  • Height Seated (Max)
    -
  • Thickness (Max)
    0.067 (1.70mm)
  • Ratings
    AEC-Q200
0 Similar Products Remaining