0015907

Lapp 0015907

Part No:

0015907

Manufacturer:

Lapp

Datasheet:

-

Package:

-

AINNX NO:

35732348-0015907

Description:

Power cable < 1 kV, for moving application

Products specifications
  • Mounting Type
    Surface
  • Conductor Material

    A conductor is a material which contains movable electric charges. In metallic conductors, such as copper or aluminum, the movable charged particles are electrons, though in other cases they can be ions or other positively charged species.

    Copper
  • Manufacturer Part Number
    12DNO45C
  • Approvals
    CSA, UL
  • Manufacturer
    Amperite
  • Timing Range
    45
  • Stranding element
    No
  • Flame retardant
    According to IEC/EN 60332-1-2
  • Permitted cable outer temperature after assembling without vibration
    -40 - 70
  • Material core insulation
    Polyvinyl chloride (PVC)
  • Conductor surface
    Bare
  • Colour outer sheath
    Grey
  • Permitted cable outer temperature during assembling/handling
    -5 - 70
  • Outer diameter approx.
    17.5
  • Screen over stranding element
    None
  • Halogen free according to IEC 60754-2
    No
  • Core identification
    Numbers
  • Nominal cross section conductor
    2.5
  • Screen over stranding
    Braiding
  • Low smoke (according to EN 61034-2)
    No
  • Min. permitted bending radius, stationary application/permanent installation
    105
  • Low smoke according to IEC 61034-2
    No
  • Nominal voltage U
    500
  • Material outer sheath
    Polyvinyl chloride (PVC)
  • Conductor category
    Class 5 = flexible
  • Voltage, Rating
    600V
  • Jacket Material
    PVC
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +70°C
  • Minimum Operating Temperature
    -40°C
  • Insulation Materials
    PVC
  • Voltage Rating (DC)
    600 V
  • Series
    ÖLFLEX 150 CY
  • Termination
    0.110 in Flat Blade
  • Wire Gauge

    a measurement of?wire?diameter.?This determines the amount of electric current the wire can safely carry, as well as its electrical resistance and weight.

    14AWG
  • Wire/Cable Gauge
    14 AWG
  • Coil Voltage
    12 VDC
  • Number of Cores
    7
  • Outer Diameter
    17.5mm
  • Mode of Operation

    There are 5 types of mode of operation, Electronic CodeBook (ECB), Cipher Block Chaining (CBC), Cipher feedback (CFB), Output Feedback (OFB), Counter Mode (CTR).

    On Delay
  • Contacts
    1NO
  • Minimum Bend Radius
    20 x 17.5 (Occasional Flexing) mm, 6 x 17.5 (Fixed Installation) mm
  • Length
    50m
0 Similar Products Remaining