LIA101

IXYS Integrated Circuits Division LIA101

Part No:

LIA101

Datasheet:

LIA101PTR

Package:

16-DIP (0.300, 7.62mm)

ROHS:

AINNX NO:

7903638-LIA101

Description:

IC OPAMP ISOLATION 2 CIRC 16DIP

Products specifications
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    16-DIP (0.300, 7.62mm)
  • Number of Pins
    16
  • Supplier Device Package
    16-DIP
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tube
  • Published
    2001
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Obsolete
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85°C
  • Min Operating Temperature
    -40°C
  • Number of Channels
    2
  • Number of Circuits
    2
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    18V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    5V
  • Operating Supply Current
    5mA
  • Current - Supply
    5mA
  • Slew Rate

    the maximum rate of output voltage change per unit time.

    0.3V/μs
  • Amplifier Type
    Isolation
  • Voltage - Supply, Single/Dual (±)
    ±5V~18V
  • Input Offset Voltage (Vos)
    3mV
  • Gain Bandwidth Product

    The gain–bandwidth product (designated as GBWP, GBW, GBP, or GB) for an amplifier is the product of the amplifier's bandwidth and the gain at which the bandwidth is measured.

    40kHz
  • Voltage - Input Offset
    3mV
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    3.75kV
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free