IRAMX16UP60B

Infineon Technologies IRAMX16UP60B

Part No:

IRAMX16UP60B

Datasheet:

IRAMX16UP60B

Package:

23-PowerSIP Module, 19 Leads, Formed Leads

ROHS:

AINNX NO:

5051871-IRAMX16UP60B

Description:

IC PWR HYBRID 600V 16A SIP2

Products specifications
  • Factory Lead Time
    13 Weeks
  • Mount
    PCB, Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    23-PowerSIP Module, 19 Leads, Formed Leads
  • Number of Pins
    23
  • Collector-Emitter Breakdown Voltage
    600V
  • SwitchingFrequency
    20kHz
  • Turn Off Delay Time

    It is the time from when Vgs drops below 90% of the gate drive voltage to when the drain current drops below 90% of the load current. It is the delay before current starts to transition in the load, and depends on Rg. Ciss.

    660 ns
  • Series
    iMOTION™
  • Published
    2005
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Obsolete
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Number of Terminations
    23
  • Type
    IGBT
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    150°C
  • Min Operating Temperature
    -40°C
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    31W
  • Terminal Position
    ZIG-ZAG
  • Number of Functions
    1
  • Supply Voltage
    15V
  • Terminal Pitch

    The center distance from one pole to the next.

    1.98mm
  • Frequency
    20kHz
  • Number of Outputs
    3
  • Voltage - Isolation
    2000Vrms
  • Output Voltage
    450V
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    15V
  • Temperature Grade

    Temperature grades represent a tire's resistance to heat and its ability to dissipate heat when tested under controlled laboratory test conditions.

    AUTOMOTIVE
  • Configuration
    3 Phase
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    20V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    12V
  • Operating Supply Current
    3.35mA
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    3.35mA
  • Power Dissipation

    the process by which an electronic or electrical device produces heat (energy loss or waste) as an undesirable derivative of its primary action.

    3W
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    16A
  • Quiescent Current

    The quiescent current is defined as the current level in the amplifier when it is producing an output of zero.

    165μA
  • Turn On Delay Time

    Turn-on delay, td(on), is the time taken to charge the input capacitance of the device before drain current conduction can start.

    590 ns
  • Collector Emitter Voltage (VCEO)
    600V
  • Max Collector Current
    16A
  • RMS Current (Irms)
    16A
  • Input Bias Current
    200μA
  • Max Junction Temperature (Tj)
    150°C
  • Height
    26.8mm
  • Length
    21.9964mm
  • Width
    5.5mm
  • REACH SVHC
    No SVHC
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining