CYV15G0204RB-BGC

Infineon CYV15G0204RB-BGC

Part No:

CYV15G0204RB-BGC

Manufacturer:

Infineon

Datasheet:

Package:

256-BGA Exposed Pad

AINNX NO:

39762819-CYV15G0204RB-BGC

Description:

IC DESERIAL HOTLINK 256LBGA

Products specifications
  • Mounting Type
    Chassis Mount
  • Package / Case
    256-BGA Exposed Pad
  • Supplier Device Package
    256-L2BGA (27x27)
  • Package
    Bulk
  • Mfr
    Sensata-Gigavac Clean Energy
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    70Ohms
  • Base Product Number
    CYV15G0204
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 65°C
  • Series
    P125
  • Voltage - Supply
    3.3V
  • Termination Style
    Stud
  • Function
    Deserializer
  • Number of Outputs
    20
  • Output Type
    LVTTL
  • Input Type
    PECL
  • Data Rate

    Data Rate is defined as the amount of data transmitted during a specified time period over a network. It is the speed at which data is transferred from one device to another or between a peripheral device and the computer. It is generally measured in Mega bits per second(Mbps) or Mega bytes per second(MBps).

    1.485Gbps
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPST-NO (DM) (1 Form X)
  • Number of Inputs
    20
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    25 ms
  • Coil Voltage
    12VDC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    1200VDC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    170 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    8 ms
  • Must Operate Voltage
    7.5 VDC
  • Contact Rating (Current)
    30 A
  • Coil Power
    2.04W
  • Must Release Voltage
    0.2 VDC
  • Features
    Sealed - Hermetically
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Infineon CYV15G0204RB-BGC.
  • Datasheets :