SS461R

Honeywell Sensing and Productivity Solutions SS461R

Part No:

SS461R

Package:

TO-226-3, TO-92-3 Short Body

ROHS:

AINNX NO:

5578416-SS461R

Description:

HONEYWELL SS461R Hall Effect Sensor, Bipolar, 20 mA, TO-92, 3 Pins, 3 V, 24 V

Products specifications
  • Factory Lead Time
    11 Weeks
  • Mount
    Surface Mount, Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    TO-226-3, TO-92-3 Short Body
  • Number of Pins
    3
  • Test Conditions
    -40°C ~ 150°C
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~150°C TA
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Published
    2010
  • JESD-609 Code
    e3
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Through Hole
  • Type
    Integrated Circuit (IC)
  • Terminal Finish
    Matte Tin (Sn)
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    DUAL OUTPUT
  • Voltage - Supply
    3V~24V
  • Function
    Latch
  • Output Type
    Open Collector
  • Max Output Current

    The maximum current that can be supplied to the load.

    20mA
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    18V
  • Leakage Current
    10μA
  • Operating Supply Current
    8mA
  • Polarization
    South Pole
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    8mA
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    20mA
  • Sensing Method
    Hall Effect
  • Max Supply Voltage (DC)
    18V
  • Min Supply Voltage (DC)
    3V
  • Sensing Range

    The sensing range of position sensors is the displacement between the sensing face of the sensor and the approaching measurement object that triggers a signal change in the sensor.

    12mT Trip, -12mT Release
  • Output Range
    20mA
  • Magnetic Field Range-Min
    -12 mT
  • Magnetic Field Range-Max
    12 mT
  • Height
    1.6mm
  • Length
    4.1mm
  • Width
    3mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining