40PC150G2A

Honeywell Sensing and Productivity Solutions 40PC150G2A

Part No:

40PC150G2A

Datasheet:

40PC Series

Package:

6-DIP Module

ROHS:

AINNX NO:

4688940-40PC150G2A

Description:

SENSOR AMP 150PSI GAUGE

Products specifications
  • Factory Lead Time
    7 Weeks
  • Mount
    PCB, Through Hole
  • Package / Case
    6-DIP Module
  • Number of Pins
    6
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    5V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -45°C~125°C
  • Series
    40PC
  • Published
    1998
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    PCB
  • Applications
    Board Mount
  • Voltage - Rated DC
    50V
  • Voltage - Supply
    4.75V~5.25V
  • Output
    0.5 V ~ 4.5 V
  • Termination Style
    PC Pin
  • Body Length or Diameter
    13.21mm
  • Body Breadth
    11.13 mm
  • Output Voltage
    4V
  • Output Type
    Analog Voltage
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    10mA
  • Max Supply Current
    10mA
  • Accuracy
    ±2.5%
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    1 ms
  • Operating Pressure

    An operating pressure is the amount of internal force applied to the walls of some type of pressure vessel during normal conditions.

    150PSI (1034.21kPa)
  • Pressure Type
    Vented Gauge
  • Port Style
    Barbless
  • Port Size
    Male - 0.18 4.57mm Tube
  • Linearity
    0.1 %
  • Maximum Pressure
    300PSI (2068.43kPa)
  • Sensors/Transducers Type
    PRESSURE SENSOR,PEIZORESISTIVE
  • Max Pressure
    300 PSI
  • Pressure Range-Max
    150 Psi
  • Pressure Sensing Mode
    GAGE
  • Features
    Amplified Output
  • REACH SVHC
    No SVHC
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Honeywell Sensing and Productivity Solutions 40PC150G2A.