Mounting Type
Surface Mount
Package / Case
6-CLCC
Supplier Device Package
6-CLCC (7x5)
Weight
698.5g
Voltage DC reading range (max.)
1000V
Dim
(L x W x H) 215 x 101 x 60 mm
Voltage metering
AC/DC
Basic accuracy
0.05%
Reading range - capacity
0.01 nF - 9999µF
Amperage reading range DC (min.)
0.1µA
Amperage reading range AC (max.)
10A
Reading range - resistance
0.1 Ω - 50MΩ
Current reading
AC/DC
A AC reading range (min.)
0.1µA
Reading category
CAT III 1000 V,CAT IV 600 V
Power supply (details)
3x AA battery
V AC reading range (max.)
1000V
A DC reading range (max.)
10A
Calibrated to
Manufacturers standards (no certificate)
Frequency reading range
0.01 Hz – 199.99kHz
Voltage reading range DC (min.)
0.1mV
Display
Digital
V AC reading range (min.)
0.1mV
Min. value storage
Yes
Relative value measurement
Yes
With display backlight
Yes
Temperature measurement
Yes
With decibel measurement (dB)
No
Harmonics analysis/power quality
No
Measuring range selection
Manual/automatic
Cable length measurement
No
Multiple display
No
Lowest resolution, resistance
0.01 Ohm
Measured value memory
No
Lowest resolution, DC voltage
0.01 mV
Max. voltage measuring circuit category
600
Milliohm measurement with 4 wire technique (Kelvin connection)
No
Nominal test voltage 500 V
No
Bluetooth interface
No
Rotational speed measuring
No
Max. current measuring range, AC
10
Scaling bar graph lineair
Yes
Nominal test voltage 100 V
No
Duty cycle measurements
Yes
Nominal test voltage 10 V
No
Max. value storage
Yes
Degree of protection (IP)
IP67
Power and energy measurement
No
Explosion-tested version
No
Lowest resolution, DC current
0.01 µA
Max. voltage measuring range, DC
1000
Max. voltage measuring range, AC
1000
Inductance measurement
No
Temperature measurement TC
Yes
Nominal test voltage 50 V
No
Temperature measurement RTD
No
Nominal test voltage 1000 V
No
Cable symmetry testing for two wire connections a-b-E
No
Capacitance measurement
Yes
Scaling bar graph logarithmic
No
Lowest resolution, AC voltage
0.01 mV
IR interface
No
With conductivity measurement
Yes
Automatic circuit breaker
No
Max. resistance measuring range
50
True RMS measurement
Yes
Nominal test voltage 250 V
No
Peak value memory
Yes
Frequency measurement
Yes
Lowest resolution, frequency
0.01 Hz
Measuring circuit category
CAT IV
Indication
Digital
Resistance test/diode test
Yes
Analogue bar graph display
Yes
Max. frequency measuring range
199.99
Max. current measuring range, DC
10
Lowest resolution, AC current
0.01 µA
Analogue bar graph display analogue/logarithmical
Yes
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-40°C ~ 85°C
Series
FemtoClock® NG
Packaging
Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.
Tray
Part Status
Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.
Active
Type
VCXO
Voltage - Supply
2.375 V ~ 2.625 V
Frequency
496MHz
Base Part Number
IDT8N4SV76BC
Interface
none
Current - Supply
136mA
Count
--
Temperature
+1090 - -200°C
Width
101mm
Height
60mm
Length
215mm