70.61.8.400.0000

Finder Relays, Inc. 70.61.8.400.0000

Part No:

70.61.8.400.0000

Manufacturer:

Finder Relays, Inc.

Datasheet:

-

Package:

-

ROHS:

AINNX NO:

5748433-70.61.8.400.0000

Description:

FINDER 70.61.8.400.0000 Phase Monitoring Relay, Loss, Rotation, 70 Series, SPDT, 6 A, DIN Rail, Screw, 480 V

Products specifications
  • Factory Lead Time
    6 Weeks
  • Mounting Type
    DIN Rail
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C~60°C
  • Series
    70
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Type
    Voltage Sensing AC, Phase Loss
  • Voltage - Rated DC
    400V
  • Voltage - Supply
    208V~240VAC
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    6A
  • Voltage - Rated AC
    400V
  • Output Type
    Relay
  • Circuit
    SPDT (1 Form C)
  • Throw Configuration
    SPDT
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    6A
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250V
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    1W
  • Contact Rating @ Voltage
    6A @ 250VAC
  • Input Current
    6A
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    Fixed, 0.50 Sec
  • Switching Current
    6A
  • Trip Range

    The maximum distance a piezo stage can move in a single axis.

    170 ~ 500V AC
  • Height
    60.8mm
  • Length
    84mm
  • Width
    17.5mm
  • REACH SVHC
    No SVHC
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Ratings
    IP20