VLT40-3203

EOS Power India Private Ltd VLT40-3203

Part No:

VLT40-3203

Package:

-

AINNX NO:

22132606-VLT40-3203

Description:

AC/DC Power Supply Triple-OUT 3.3V/5V/-12V 6A/3A/0.5A 40W Medical 6-Pin

Products specifications
  • Weight
    150 g
  • ECCN (US)
    EAR99
  • HTS
    8504.40.95.10
  • Input/Output Type
    AC/DC
  • Output Voltage (V)
    5|-12|3.3
  • Output Current (A)
    0.5|6|3
  • Output Power (W)
    40
  • Minimum AC Input Voltage (V)
    90
  • Maximum AC Input Voltage (V)
    264
  • Maximum Input Current (A)
    1.1(rms)
  • Input Frequency (Hz)
    47 to 63
  • Efficiency (%)
    75(Typ)
  • Input Connector Type
    Pin Terminal Block
  • Output Connector Type
    Pin Terminal Block
  • Power Indicator
    No
  • Ripple & Noise
    1%
  • Medical
    No
  • Minimum Operating Temperature (°C)
    0
  • Maximum Operating Temperature (°C)
    50
  • Mounting
    Screw
  • Package Height
    27.18(Max)
  • Package Length
    101.6
  • Package Width
    50.8
  • PCB changed
    6
  • RoHS
    Compliant
  • Tolerance
    ±3|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5|±5
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Type
    Regulated
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    50 °C
  • Min Operating Temperature
    0 °C
  • Power Rating
    40 W
  • Depth
    27.18 mm
  • Style
    Open Frame
  • Pin Count

    a count of all of the component leads (or pins)

    6
  • Number of Outputs
    3
  • Efficiency
    75 %
  • Output Voltage
    5 V
  • Output Type
    Fixed
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    6 A
  • Line Regulation

    Line regulation is the ability of a power supply to maintain a constant output voltage despite changes to the input voltage, with the output current drawn from the power supply remaining constant.

    0.3%
  • Load Regulation

    Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

    5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|5%|0.5%
  • Width
    50.8 mm
  • Length
    101.6 mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    Yes with exemptions
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for EOS Power India Private Ltd VLT40-3203.