Surface Mount
having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.
NO
Number of Terminals
7
Product Weight (g)
150
ECCN (US)
EAR99
Input/Output Type
AC/DC
Output Voltage (V)
24
Output Current (A)
4.2(Forced Air)|3.3(Convection)
Output Power (W)
100
Minimum AC Input Voltage (V)
90
Maximum AC Input Voltage (V)
264
Minimum Isolation Voltage
4000VAC
Maximum Input Current (A)
2.5
Input Frequency (Hz)
47 to 63
Efficiency (%)
89.3(Typ)
Configurable
No
Input Connector Type
JST RCY Male
Output Connector Type
JST RCY Male
Power Indicator
No
Ripple & Noise
58.4mV
Medical
Yes
Minimum Operating Temperature (°C)
-10
Maximum Operating Temperature (°C)
70
Mounting
Screw
Package Height
31.8
Package Length
101.6
Package Width
50.8
PCB changed
6
Package Description
,
Package Style
MICROELECTRONIC ASSEMBLY
Package Body Material
UNSPECIFIED
Operating Temperature-Min
-10 °C
Reflow Temperature-Max (s)
NOT SPECIFIED
Operating Temperature-Max
70 °C
Rohs Code
Yes
Input Voltage-Max
264 V
Manufacturer Part Number
MDS-100BPS24B
Approvals
CSA, EN, IEC, UL
Load Regulation-Max
1%
Package Shape
RECTANGLE
Manufacturer
Delta Electronics Inc
Part Life Cycle Code
Active
Input Voltage-Min
90 V
Ihs Manufacturer
DELTA ELECTRONICS INC
Output Voltage-Nom
24 V
Line Regulation-Max
0.5%
Risk Rank
5.74
Part Status
Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.
Active
Type
Switching
Technology
HYBRID
Terminal Position
UNSPECIFIED
Terminal Form
Occurring at or forming the end of a series, succession, or the like; closing; concluding.
UNSPECIFIED
Peak Reflow Temperature (Cel)
NOT SPECIFIED
Number of Functions
1
Style
Open Frame
Reach Compliance Code
compliant
Pin Count
a count of all of the component leads (or pins)
6
JESD-30 Code
R-XXFM-X7
Number of Outputs
1
Output Type
Fixed
Input Voltage-Nom
100 V
Temperature Grade
Temperature grades represent a tire's resistance to heat and its ability to dissipate heat when tested under controlled laboratory test conditions.
COMMERCIAL
Trim/Adjustable Output
NO
Analog IC - Other Type
AC-DC REGULATED POWER SUPPLY MODULE
Protections
THERMAL; OUTPUT CURRENT; OUTPUT OVER VOLTAGE
Control Mode
VOLTAGE-MODE
Total Power Output-Max
100 W
Output Voltage-Max
24.36 V
Output Voltage-Min
23.64 V
Line Regulation
Line regulation is the ability of a power supply to maintain a constant output voltage despite changes to the input voltage, with the output current drawn from the power supply remaining constant.
0.5%
Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).
1%
Ripple Voltage (Main Out)
0.0206444 Vrms
Efficiency (Main Output)
89.3%
RoHS Status
RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.
RoHS Compliant