Wire length
0m
Ambient temperature (operation)
- 30 °C ~ 50 °C
Ambient temperature (storage/transportation)
- 40 °C ~ 80 °C
Maximum altitude
5000m(Above sea level )
IP class
IP55(coupling)
Maximum charge power
250KW
Power pin quantity
9 (DC+,DC-,PE,A+,A-,S+,S-,CCS1,CCS2)
Rated current of high-power contacts
250
Power contact rated voltage
750
Quantity of signal contacts
4(S+,S-,CCS1,CCS2)
Signal contact rated current
2
Signal contact rated voltage
30
Signal transmission type
Pulse width adjustment
Connection method precautions
Crimp connection, cannot be disconnected
Temperature measurement
2x Pt 1000 (DIN EN 60751)
Insert / pull out cycle
10000
Pullout force
< 140N
Available installation location
Installation in front of the board
Limit of the installation location
Only allow 0 to 90 degrees frontal tilt
Shell color
black
Customization basis
Provided according to customer requirements
Contact surface material
Ag
Marking material
Plastic
Lock type
Secured by locking device after insertion
Recommended measured current
1 mA (1 V at 0°C
)
Recommendation to measure tolerance on current sensors
±1K
Temperature coefficient (TCR)
3850 ppm/K
Shutdown temperature
90 °C Equivalent to Pt 1000 value 1346.5 Ω
REACH
conform
China RoHS
conform
Cable composition
2 x 80 mm² + 1 x 25 mm² + 2 × 4 mm² + 3× 0.75 mm²
Depth
84.2mm
Standard
DIN EN 60751
Phase
3