DAR71210F

Cynergy 3 DAR71210F

Part No:

DAR71210F

Manufacturer:

Cynergy 3

Package:

-

ROHS:

AINNX NO:

8477442-DAR71210F

Category:

Reed Relays

Description:

RELAY REED SPST-NO 3A 12V

Products specifications
  • Factory Lead Time
    8 Weeks
  • Mount
    PCB, Through Hole
  • Mounting Type
    Through Hole
  • Number of Pins
    4
  • CoilResistance
    150Ohm
  • Contact Materials
    Rhodium (Rh)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C~70°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tray
  • Series
    DA
  • Published
    2008
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Wire Leads
  • ECCN Code
    EAR99
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    OPERATE AND RELEASE TIME WITH DIODE
  • Voltage - Rated DC
    12V
  • Depth
    15.8mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    4A
  • Termination Style
    PC Pin, Wire Leads
  • Number of Contacts
    1
  • Contact Resistance
    50mOhm
  • Contact Current(DC)-Max
    3A
  • Throw Configuration
    SPST
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPST-NO (1 Form A)
  • Relay Type
    Reed
  • Contact Current(AC)-Max
    3A
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    3ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    1000VAC 1000VDC -Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    80mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    2ms
  • Must Operate Voltage
    9VDC
  • Coil Power
    960mW
  • Must Release Voltage
    1.25VDC
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    12V
  • Coil/Input Supply Type
    DC
  • Switching Current
    3A
  • Height
    18.5mm
  • Length
    60mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Cynergy 3 DAR71210F.