VSK-S2-15U

CUI Inc. VSK-S2-15U

Part No:

VSK-S2-15U

Manufacturer:

CUI Inc.

Datasheet:

VSK-S2 Series

Package:

4-DIP Module

ROHS:

AINNX NO:

3671772-VSK-S2-15U

Description:

POWER SUPPLY SWITCHING 15V 2W

Products specifications
  • Factory Lead Time
    10 Weeks
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    4-DIP Module
  • Weight
    0.044lb 19.96g
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C~70°C With Derating
  • Series
    VSK-S2 (2W)
  • Published
    2015
  • Size / Dimension
    1.33Lx0.87W x 0.71 H 33.7mmx22.2mmx18.0mm
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Type
    Enclosed
  • Applications
    ITE (Commercial)
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    2W
  • Reach Compliance Code
    unknown
  • Number of Outputs
    1
  • Approval Agency
    CE, cULus
  • Efficiency
    76%
  • Output Voltage
    15V
  • Max Output Current

    The maximum current that can be supplied to the load.

    133mA
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    2W
  • Current - Output 1
    133mA
  • Line Regulation

    Line regulation is the ability of a power supply to maintain a constant output voltage despite changes to the input voltage, with the output current drawn from the power supply remaining constant.

    ±2%
  • Load Regulation

    Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

    ±5%
  • Features
    OCP, SCP
  • Height
    18.034mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free