88826105

Crouzet 88826105

Part No:

88826105

Manufacturer:

Crouzet

Datasheet:

88826xxx

Package:

100

ROHS:

AINNX NO:

5356378-88826105

Description:

CROUZET AUTOMATION 88 826 105 TIMER, MULTIFUNCTION, 1S-100H, 240VAC

Products specifications
  • Mount
    DIN Rail
  • Mounting Type
    DIN Rail
  • Package / Case
    100
  • Number of Pins
    6
  • Contact Materials
    Silver
  • Series
    MUR1
  • Published
    2001
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Obsolete
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Termination
    Screw
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    60°C
  • Min Operating Temperature
    -20°C
  • Voltage - Supply
    24V~240VAC 24VDC
  • Depth
    60mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    8A
  • Termination Style
    Screw Terminal
  • Function
    Programmable (Multi-Function)
  • Voltage - Rated AC
    250V
  • Approval Agency
    CE, CSA, UL
  • Number of Contacts
    1
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    240V
  • Circuit
    SPDT (1 Form C)
  • Max Current Rating
    8A
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    10A
  • Throw Configuration
    SPDT
  • Accuracy
    0.5 %
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    8A
  • Relay Type
    Mechanical Relay
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    1.5W
  • Contact Rating @ Voltage
    8A @ 250VAC
  • Coil Voltage (DC)
    24V
  • Max Supply Voltage (AC)
    240V
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    0.1 Sec ~ 100 Hrs
  • Timing Adjustment Method
    Screwdriver Slot
  • Timing Initiate Method

    The initiation time (also known as release time) is the time at which the process goes from the waiting to the ready state. An aperiodic process is by definition initiated by an event, such as external data arriving or data computed by another process.

    Input Voltage, Trigger Signal
  • Nominal Input Voltage (AC)
    240V
  • Height
    81mm
  • Length
    81mm
  • Width
    17.5mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining