Mounting Type
Through Hole
Number of Terminals
8
End Contact Material
Rhodium
ECCN (US)
EAR99
DC Coil Voltage (V)
24
Coil Current (mA)
11.16
Coil Resistance (Ohm)
2.15K
Maximum Contact Resistance (mOhm)
150
Insulation Resistance (Ohm)
10G
Maximum Pick-Up Voltage
18VDC
Maximum AC Switching Voltage (V)
100
Maximum Switching Current (A)
0.5
Minimum Dropout Voltage
2VDC
Maximum Carry Current (A)
1
Isolation Across Contacts
200VDC
Isolation Across Coil and Contacts
1.4KVDC
Maximum Switching Power
10W
Operate Time (ms)
1
Release Time (ms)
0.05
LED Indicator
No
Push to Test Button
No
Mounting
Through Hole
Contact Materials
Rhodium
Relay Construction
Non-Latching
Seal
Unsealed
Minimum Operating Temperature (°C)
-40
Maximum Operating Temperature (°C)
70
Package Type
DIP
Product Depth (mm)
7.85
Package
Tray
Mfr
Celduc Inc.
Product Status
Active
CoilResistance
2.15 kOhms
Coil Voltage-Nom
24 V
Operating Temperature-Min
-40 °C
Operating Temperature-Max
70 °C
Manufacturer Part Number
D31A7110
Manufacturer
Celduc Group
Part Life Cycle Code
Active
Ihs Manufacturer
CELDUC RELAIS
ElectricalLife
1000000 Cycle(s)
Risk Rank
5.73
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-40°C ~ 70°C
Series
-
Part Status
Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.
Active
Type
Dry
Reach Compliance Code
unknown
Termination Style
PC Pin
Body Length or Diameter
19.9 mm
Body Breadth
6.9 mm
Physical Dimension
19.9mm x 6.9mm x 5.5mm
Contact Resistance
150 mΩ
Insulation Resistance
The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.
10000000000 Ω
Contact Current(DC)-Max
1 A
Contact Voltage(DC)-Max
100 V
Termination Type
SOLDER
Contact Form
A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.
SPST-NO (1 Form A)
Relay Type
DRY REED RELAY
Operate Time
The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.
1 ms
Coil Voltage
24VDC
Coil Type
There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.
Non Latching
Switching Voltage
The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.
100VDC - Max
Coil Current
A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.
11.2 mA
Release Time
In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued
50 µs
Contact (DC) Max Rating R Load
Must Operate Voltage
18 VDC
Contact Rating (Current)
500 mA
Must Release Voltage
2 VDC
Contact/Output Supply Type
DC
Relay Action
LATCHED
Coil/Input Supply Type
DC
PCB Hole Count
8
Seal Rating
-
Dielectric Strength Between Open Contacts
200 Vrms
Input Switching Control Type
Random
Dielectric Strength Between Coil and Contacts
1400 Vrms
Contact (DC) Max Power Rating R Load
Relay Function
SPST
Contact Arrangement
SPST-NO
Coil Voltage(DC)-Max
32 V
Relay Form
1 FORM A
Coil Operate Voltage(DC)
18 V
Coil Release Voltage(DC)
2 V
Features
Diode
Terminal Length
0.0031 inch
Electrical Life Cycles
1M
Coil Suppression Diode
A coil spike suppression diode is a protection device across the contactor coil. Energizing the contactor coil creates a magnetic field that forces the solenoid arm to engage the contacts. When the contactor is turned off, the magnetic field collapses causing a back “voltage spike” that can damage the controller.
Yes
Product Length (mm)
19.1
Body Height
5.5 mm
Product Height (mm)
6.8
RoHS Status
RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.
RoHS Compliant