PMT20RI

Carlo Gavazzi Inc. PMT20RI

Part No:

PMT20RI

Manufacturer:

Carlo Gavazzi Inc.

Package:

-

ROHS:

AINNX NO:

5962224-PMT20RI

Description:

Through Beam(Receiver)PES Maximum of 20m Detection Range, Block Style, IP67

Products specifications
  • Factory Lead Time
    7 Weeks
  • Mount
    Through Hole
  • Housing Material
    PC
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C~55°C
  • Series
    PMT
  • Published
    2006
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8542.39.00.01
  • Voltage - Supply
    10.8V~264V
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IEC 60529 IP67
  • Output Configuration
    Relay - Light-ON
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    20ms
  • Adjustment Type
    Adjustable, 1-Turn Potentiometer
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    787.402 (20m)
  • Sensing Method
    Through-Beam
  • Connection Method

    the systematic way of connecting the Power Plant (units) to the power grid.

    Cable
  • Light Source

    an optical transmitter that is paired with an optical receiver, both of which are connected to electrically based devices or systems.

    Infrared (880nm)
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Ratings
    IP67
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Carlo Gavazzi Inc. PMT20RI.