HCPL-7800-500E

Broadcom Limited HCPL-7800-500E

Part No:

HCPL-7800-500E

Manufacturer:

Broadcom Limited

Package:

8-SMD, Gull Wing

ROHS:

AINNX NO:

7878069-HCPL-7800-500E

Description:

BROADCOM LIMITED HCPL-7800-500E ISOLATION AMP, 100KHZ, 3.75KV, SMDIP-8

Products specifications
  • Factory Lead Time
    17 Weeks
  • Mount
    Surface Mount
  • Mounting Type
    Surface Mount
  • Package / Case
    8-SMD, Gull Wing
  • Number of Pins
    8
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Published
    2004
  • JESD-609 Code
    e3
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Number of Terminations
    8
  • ECCN Code
    EAR99
  • Terminal Finish
    Matte Tin (Sn)
  • Terminal Position
    DUAL
  • Peak Reflow Temperature (Cel)
    260
  • Number of Functions
    1
  • Supply Voltage
    5V
  • Terminal Pitch

    The center distance from one pole to the next.

    2.54mm
  • Time@Peak Reflow Temperature-Max (s)
    40
  • Base Part Number
    HCPL-7800
  • Output Voltage
    3.8V
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    5V
  • Power Supplies

    an electronic circuit that converts the voltage of an alternating current (AC) into a direct current (DC) voltage.?

    5V
  • Number of Channels
    1
  • Number of Circuits
    1
  • Operating Supply Current
    10.9mA
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    16mA
  • Slew Rate

    the maximum rate of output voltage change per unit time.

    10000 V/μs
  • Amplifier Type
    Isolation
  • Common Mode Rejection Ratio
    76 dB
  • Current - Input Bias
    500nA
  • Voltage - Supply, Single/Dual (±)
    4.5V~5.5V
  • Output Current per Channel
    16mA
  • Input Offset Voltage (Vos)
    300μV
  • -3db Bandwidth
    100MHz
  • Input Current
    10.86mA
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    3.75kV
  • Voltage Gain-Min
    7.76
  • Height Seated (Max)
    4.455mm
  • REACH SVHC
    No SVHC
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Broadcom Limited HCPL-7800-500E.