HCPL-316J-000E

Broadcom Limited HCPL-316J-000E

Part No:

HCPL-316J-000E

Manufacturer:

Broadcom Limited

Datasheet:

-

Package:

16-SOIC (0.295, 7.50mm Width)

ROHS:

AINNX NO:

1519529-HCPL-316J-000E

Description:

OPTOISO 5KV 2CH GATE DRIVER 16SO

Products specifications
  • Factory Lead Time
    22 Weeks
  • Contact Plating

    Contact plating (finish) provides corrosion protection for base metals and optimizes the mechanical and electrical properties of the contact interfaces.

    Tin
  • Mount
    Surface Mount
  • Mounting Type
    Surface Mount
  • Package / Case
    16-SOIC (0.295, 7.50mm Width)
  • Number of Pins
    16
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~100°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tube
  • Published
    2000
  • JESD-609 Code
    e3
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Number of Terminations
    16
  • ECCN Code
    EAR99
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    1.2W
  • Terminal Position
    DUAL
  • Terminal Form

    Occurring at or forming the end of a series, succession, or the like; closing; concluding.

    GULL WING
  • Peak Reflow Temperature (Cel)
    260
  • Number of Functions
    1
  • Supply Voltage
    5V
  • Approval Agency
    CSA, IEC/EN/DIN, UR
  • Voltage - Isolation
    5000Vrms
  • Output Voltage
    30V
  • Max Output Current

    The maximum current that can be supplied to the load.

    2.5A
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    5V
  • Number of Channels
    2
  • Number of Circuits
    1
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    30V
  • Propagation Delay

    the flight time of packets over the transmission link and is limited by the speed of light.

    500 ns
  • Turn On Delay Time

    Turn-on delay, td(on), is the time taken to charge the input capacitance of the device before drain current conduction can start.

    500 ns
  • Max Output Voltage

    The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.

    35V
  • Direction
    Unidirectional
  • Rise Time

    In electronics, when describing a voltage or current step function, rise time is the time taken by a signal to change from a specified low value to a specified high value.

    500ns
  • Fall Time (Typ)
    100 ns
  • Rise / Fall Time (Typ)
    100ns 100ns
  • Interface IC Type
    BUFFER OR INVERTER BASED MOSFET DRIVER
  • Turn On Time

    The time that it takes a gate circuit to allow a current to reach its full value.

    0.5 μs
  • Input Current
    22mA
  • Propagation Delay tpLH / tpHL (Max)
    500ns, 500ns
  • Common Mode Transient Immunity (Min)
    15kV/μs
  • High Side Driver
    NO
  • Turn Off Time
    0.5 μs
  • Pulse Width Distortion (PWD)
    300 ns
  • Voltage - Output Supply
    15V~30V
  • REACH SVHC
    No SVHC
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining