Factory Lead Time
12 Weeks
ECCN (US)
EAR99
Power Supply Color
Black
Input/Output Type
AC/DC
Output Voltage (V)
15|15|15|15|15|15|15|15|15|15|15|15|15|15|15|15|15|15|15
Output Current (A)
5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)|5(Typ)
Output Power (W)
150
Minimum AC Input Voltage (V)
85
Typical AC Input Voltage (V)
230
Maximum AC Input Voltage (V)
264
Minimum DC Input Voltage (V)
88
Typical DC Input Voltage (V)
310
Maximum DC Input Voltage (V)
372
Minimum Isolation Voltage
2000VAC
Maximum Input Current (A)
0.57(Typ)
Input Frequency (Hz)
47 to 440
Efficiency (%)
83(Min)
Configurable
No
Power Indicator
Yes
Medical
No
Minimum Operating Temperature (°C)
-40
Maximum Operating Temperature (°C)
71
Mounting
Chassis
Package Height
80
Package Length
171.9(Max)
Package Width
111
PCB changed
15
Maximum Operating Temperature
the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.
+ 71 C
Open Frame/Enclosed
Enclosed
Minimum Operating Temperature
- 40 C
Factory Pack QuantityFactory Pack Quantity
6
Mounting Styles
Panel
Output Current-Channel 2
5 A
Manufacturer
Bel Power Solutions
Brand
Bel Power Solutions
Output Voltage-Channel 2
15 VDC
Package Description
,
Manufacturer Part Number
LK2540-9ERG
Part Life Cycle Code
Active
Ihs Manufacturer
BEL FUSE INC
Risk Rank
5.77
Series
K
Type
Regulated
Subcategory
AC-DC Power Supply
Style
Enclosed
Reach Compliance Code
compliant
Pin Count
a count of all of the component leads (or pins)
15
Number of Outputs
2
Efficiency
83 %
Output Type
Fixed
Analog IC - Other Type
AC-DC REGULATED POWER SUPPLY MODULE
Output Power
That power available at a specified output of a device under specified conditions of operation.
150 W
Product Type
a group of products which fulfill a similar need for a market segment or market as a whole.
Switching Power Supplies
Operating Temperature Range
An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).
- 40 C to + 71 C
Line Regulation
Line regulation is the ability of a power supply to maintain a constant output voltage despite changes to the input voltage, with the output current drawn from the power supply remaining constant.
25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV|25mV
Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).
-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV|-50mV
Product
Switching Supplies
Input Voltage
100 VAC to 240 VAC, 88 VDC to 372 VDC
Product Category
a particular group of related products.
Switching Power Supplies
Width
111 mm
Height
60 mm
Length
171 mm
RoHS Status
RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.
RoHS Compliant