KLT1C12DC12

Asco KLT1C12DC12

Part No:

KLT1C12DC12

Manufacturer:

Asco

Datasheet:

-

Package:

-

AINNX NO:

33514885-KLT1C12DC12

Description:

Power Relay 12VDC 12A SPDT(19x15.5x15.5)mm THT

Products specifications
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Number of Pins
    5
  • Weight
    12
  • Number of Terminals
    5
  • End Contact Material
    Silver Cadmium Oxide
  • Voltage Rating (DC)
    28 V
  • Voltage Rating (AC)
    120 V
  • CoilResistance
    400 Ω
  • RoHS
    Non-Compliant
  • Coil Voltage-Nom
    12
  • Operating Temperature-Min
    -40
  • ElectricalLife
    100000
  • Package
    Tube
  • Base Product Number
    KLT1C12D
  • Mfr
    Hasco Relays
  • Product Status
    Active
  • Contact Materials
    Silver Alloy
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40 to 85 °C
  • Series
    KLT
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85 °C
  • Min Operating Temperature
    -40 °C
  • Pitch
    5.0800
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    12 A
  • Pin Count

    a count of all of the component leads (or pins)

    4
  • Reference Standard
    CSA; TUV; UL
  • Termination Style
    PC Pin
  • Body Length or Diameter
    19
  • Number of Contacts
    1
  • Body Breadth
    15.5
  • Physical Dimension
    19mm x 15.5mm x 15.5mm
  • Contact Resistance
    50
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    100000000
  • Contact Current(DC)-Max
    12
  • Contact Voltage(DC)-Max
    28
  • Max Voltage Rating (AC)
    120 V
  • Termination Type
    SOLDER
  • Max Current Rating
    12 A
  • Throw Configuration
    SPDT
  • Max Voltage Rating (DC)
    28 V
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Contact Current(AC)-Max
    12
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    8
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non-Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    277VAC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    30 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    5
  • Must Operate Voltage
    9 VDC
  • Contact Rating (Current)
    12 A
  • Coil Power
    360 mW
  • Must Release Voltage
    1.2 VDC
  • Contact Voltage(AC)-Max
    240
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    LATCHED
  • Coil Voltage (DC)
    12 V
  • Coil/Input Supply Type
    DC
  • PCB Hole Count
    5
  • Dielectric Strength Between Open Contacts
    750
  • Input Switching Control Type
    Random
  • Coil Insulation
    Class B
  • Dielectric Strength Between Coil and Contacts
    1500
  • Switching Current
    12 A
  • Relay Function
    SPDT
  • Coil Voltage(DC)-Max
    15.6
  • Relay Form
    1 FORM C
  • Coil Operate Voltage(DC)
    9
  • Coil Release Voltage(DC)
    1.2
  • Terminal Length
    .003
  • Product Length
    7
  • Product Width
    5 mm
  • Height
    15.9 mm
  • Body Height
    15.5
0 Similar Products Remaining