LCM1500Q-T

Artesyn Embedded Technologies LCM1500Q-T

Part No:

LCM1500Q-T

Package:

-

ROHS:

AINNX NO:

22509523-LCM1500Q-T

Description:

AC/DC Power Supply Single-OUT 24V 67A 1500W

Products specifications
  • Mounting Type
    Chassis Mount
  • Weight
    1.9kg
  • Input/Output Type
    AC/DC
  • Output Voltage (V)
    24
  • Output Current (A)
    67
  • Output Power (W)
    1500
  • Minimum AC Input Voltage (V)
    90
  • Typical AC Input Voltage (V)
    115|230
  • Maximum AC Input Voltage (V)
    264
  • Minimum Isolation Voltage
    4000VAC
  • Maximum Input Current (A)
    18(rms)
  • Input Frequency (Hz)
    47 to 440
  • Efficiency (%)
    91(Typ)
  • Configurable
    No
  • Input Connector Type
    Screw Terminal Block
  • Output Connector Type
    Screw Terminal Block
  • Power Indicator
    Yes
  • Ripple & Noise
    240mV
  • Medical
    Yes
  • Minimum Operating Temperature (°C)
    -40
  • Maximum Operating Temperature (°C)
    70
  • Mounting
    Chassis
  • Package Height
    61.7
  • Package Length
    254
  • Package Width
    132
  • Minimum Temperature
    -40°C
  • Package Type
    Enclosed
  • Maximum Temperature
    +70°C
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 70 C
  • Unit Weight
    5.140 lbs
  • Open Frame/Enclosed
    Enclosed
  • Minimum Operating Temperature
    - 40 C
  • Factory Pack QuantityFactory Pack Quantity
    10
  • Mounting Styles
    Rack
  • Input Frequency

    The Input Frequency refers to the frequency that mobiles and portables transmit on to access a Repeater.

    47 Hz to 440 Hz
  • Manufacturer
    Artesyn Embedded Technologies
  • Brand
    Artesyn Embedded Technologies
  • RoHS
    Details
  • Package
    Box
  • Voltage - Output 5
    -
  • Voltage-Output 1
    24V
  • Voltage - Output 6
    -
  • Mfr
    Artesyn Embedded Power
  • Product Status
    Active
  • Standard Number
    60601-1; 62368-1
  • Series
    LCM1500
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 70°C (With Derating)
  • Size / Dimension
    10.00 L x 5.20 W x 2.43 H (254.0mm x 132.0mm x 61.7mm)
  • Tolerance
    ±0.5
  • Type
    Regulated
  • Applications
    ITE (Commercial), Medical
  • Power (Watts)
    1500W
  • Subcategory
    AC-DC Power Supply
  • Power Rating
    1.5kW
  • Depth
    61mm
  • Style
    Enclosed
  • Number of Outputs
    1
  • Approval Agency
    CB, CE, cUL, TUV, UL
  • Efficiency
    91%
  • Voltage - Isolation
    4 kV
  • Output Voltage
    24V dc
  • Output Type
    Fixed
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    67A
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    1.5 kW
  • Voltage - Output 2
    -
  • Current - Output 1
    67 A
  • Product Type

    a group of products which fulfill a similar need for a market segment or market as a whole.

    Rackmount Power Supplies
  • Voltage - Output 3
    -
  • Operating Temperature Range

    An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).

    - 40 C to + 70 C
  • Voltage - Output 4
    -
  • Minimum Load Required
    No
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    4 kVrms
  • Load Regulation

    Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

    Regulated
  • Product
    Front End Supplies
  • Features
    Adjustable Output, DC Input Capable, PFC, Remote Sense, Universal Input
  • Input Voltage
    90 → 264V ac
  • Product Category

    a particular group of related products.

    Rack Mount Power Supplies
  • Width
    132mm
  • Length
    264.7mm
  • Height
    2.5 in
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Artesyn Embedded Technologies LCM1500Q-T.