Lifecycle Status
Production (Last Updated: 3 weeks ago)
Mount
Surface Mount
Package / Case
LGA
Mounting Type
Surface Mount
Surface Mount
having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.
YES
Number of Pins
25
Supplier Device Package
25-LGA (6.25x6.25)
Number of Terminals
25
Schedule B
8542390000, 8542390000/8542390000, 8542390000/8542390000/8542390000, 8542390000/8542390000/8542390000/8542390000
Voltage-Output 1
5.5 V
Manufacturer Lifecycle Status
PRODUCTION (Last Updated: 3 weeks ago)
RoHS
Compliant
SwitchingFrequency
1 MHz
Operating Temperature (Max.)
125C
On/Off Logic
POSITIVE
Operating Temperature Classification
Automotive
DC to DC Converter Type
Step Down
Package Type
LGA
Product Depth (mm)
6.25(mm)
Operating Temp Range
-40C to 125C
Mounting Styles
Surface Mount
Switching Regulator
Yes
Rad Hardened
No
Operating Temperature (Min.)
-40C
Mounting
Surface Mount
Moisture Sensitive
Yes
Development Kit
DC2249A
Maximum Operating Temperature
the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.
+ 125 C
Unit Weight
0.059825 oz
Minimum Operating Temperature
- 40 C
Factory Pack QuantityFactory Pack Quantity
260
Manufacturer
Analog Devices Inc.
Brand
Analog Devices
Input Voltage-Max
20 V
Input Voltage-Min
3.1 V
Tradename
uModule
Package
Tray
Base Product Number
LTM4622
Mfr
Analog Devices Inc.
Product Status
Active
Package Description
LGA,
Package Style
GRID ARRAY, THIN PROFILE, FINE PITCH
Moisture Sensitivity Levels
4
Package Body Material
PLASTIC/EPOXY
Manufacturer Package Code
05-08-1949
Operating Temperature-Min
-40 °C
Reflow Temperature-Max (s)
30
Operating Temperature-Max
125 °C
Rohs Code
No
Manufacturer Part Number
LTM4622IV#PBF
Package Code
LGA
Package Shape
SQUARE
Part Life Cycle Code
Active
Ihs Manufacturer
ANALOG DEVICES INC
Risk Rank
2.31
Usage Level
Automotive grade
Packaging
Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.
Tray
Series
LTM4622
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-40°C ~ 125°C
Size / Dimension
0.25 L x 0.25 W x 0.07 H (6.3mm x 6.3mm x 1.8mm)
JESD-609 Code
e4
Pbfree Code
No
Type
Step Down
Terminal Finish
Gold (Au)
Max Operating Temperature
The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.
125 °C
Min Operating Temperature
-40 °C
Applications
ITE (Commercial)
Additional Feature
Any Feature, including a modified Existing Feature, that is not an Existing Feature.
OUTPUT VOLTAGE RANGE FROM 0.6 VOLT TO 5.5 VOLT
Subcategory
PMIC - Power Management ICs
Terminal Position
BOTTOM
Terminal Form
Occurring at or forming the end of a series, succession, or the like; closing; concluding.
BUTT
Peak Reflow Temperature (Cel)
260
Number of Functions
1
Terminal Pitch
The center distance from one pole to the next.
1.27 mm
Reach Compliance Code
compliant
Pin Count
a count of all of the component leads (or pins)
25
JESD-30 Code
S-XBGA-B25
Number of Outputs
2
Efficiency
-
Voltage - Input (Max)
20V
Output Voltage
1.5 mV
Output Type
Adjustable
Brand Name
Analog Devices Inc
Max Output Current
The maximum current that can be supplied to the load.
2.5 A
Voltage - Input (Min)
3.6V
Input Voltage-Nom
12 V
Temperature Grade
Temperature grades represent a tire's resistance to heat and its ability to dissipate heat when tested under controlled laboratory test conditions.
AUTOMOTIVE
Max Supply Voltage
In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.
20 V
Min Supply Voltage
The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.
3.6 V
Analog IC - Other Type
SWITCHING REGULATOR
Operating Supply Current
11 mA
Current - Output (Max)
2.5A, 2.5A
Nominal Supply Current
Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.
350 mA
Output Current
The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.
2.5 A
Quiescent Current
The quiescent current is defined as the current level in the amplifier when it is producing an output of zero.
45 uA
Accuracy
1 %
Max Output Voltage
The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.
5.5 V
Voltage - Output 2
0.6 ~ 5.5V
Input Voltage (Min)
3.6(V)
Topology
Buck
Min Input Voltage
3.6 V
Control Mode
CURRENT-MODE
Max Input Voltage
20 V
Control Technique
PULSE WIDTH MODULATION
Seated Height-Max
2.62 mm
Product Type
a group of products which fulfill a similar need for a market segment or market as a whole.
Switching Voltage Regulators
Voltage - Output 3
-
Min Output Voltage
600 mV
Switcher Configuration
BUCK
Voltage - Output 4
-
Switching Frequency-Max
1000 kHz
Screening Level
Automotive
Isolation
Non-Isolated
Isolation Voltage
Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.
Not Required(V)
Max Junction Temperature (Tj)
120 °C
Line Regulation
Line regulation is the ability of a power supply to maintain a constant output voltage despite changes to the input voltage, with the output current drawn from the power supply remaining constant.
0.1%/V
Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).
1%
Features
OCP, OTP, OVP
Input Voltage
3.6 TO 20(V)
Shutdown
Shutdown
Product Category
a particular group of related products.
Switching Voltage Regulators
Product Length (mm)
6.25(mm)
Width
6.35 mm
Height
1.778 mm
Length
6.35 mm
Product Height (mm)
1.82(mm)
REACH SVHC
No SVHC