UX4C00

Advanced Energy UX4C00

Part No:

UX4C00

Manufacturer:

Advanced Energy

Datasheet:

-

Package:

-

AINNX NO:

31535145-UX4C00

Description:

Modular Power Supplies 4-slot, 600W powerPac with IEC input connector & conformal coat

Products specifications
  • RoHS
    Details
  • Open Frame/Enclosed
    Enclosed
  • Mounting Styles
    Panel
  • Approvals
    UL/EN60601-1, UL/EN60950
  • Input Frequency

    The Input Frequency refers to the frequency that mobiles and portables transmit on to access a Repeater.

    47 Hz to 440 Hz
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 70 C
  • Minimum Operating Temperature
    - 40 C
  • Factory Pack QuantityFactory Pack Quantity
    5
  • Unit Weight
    12.787 lbs
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Series
    Ultimod/Xgen
  • Type
    Unconfigured Power Supply
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    600 W
  • Operating Temperature Range

    An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).

    - 40 C to + 70 C
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    4 kVrms
  • Load Regulation

    Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

    Regulated
  • Product
    Modular Power Supplies
  • Compliance
    UL/EN60601-1, UL/EN60950
  • Input Voltage
    85 VAC to 264 VAC, 120 VDC to 380 VDC